National Repository of Grey Literature 13 records found  1 - 10next  jump to record: Search took 0.01 seconds. 
Continuous monitoring of anthraquinone-based anticancer drugs by amperometric technique
Skalová, Štěpánka ; Fischer, J. ; Barek, J. ; Navrátil, Tomáš ; Krejčí, J. ; Kučerová, R. ; Vyskočil, V.
This contribution is focused on the development of electroanalytical methods for the monitoring of anthraquinone-based anticancer drugs in physiological solution by combination of liquid-flow system and dialysis catheter, possibly inserted into blood circulation of patients. For this purpose, amperometric detection with dual glassy carbon electrode was developed and derivate of these drugs, anthraquinone-2-sulphonate, was used as a model compound. Two different flow rates of carrier solution (physiological solution) were tested (specifically, 1 and 5 mu L min(-1)) and the dependence of peak currents of anthraquinone-2-sulphonate on its concentration was verified
Development of Novel Electrochemical Methods Using Various Membrane Materials for Monitoring of Selected Anticancer Drugs and Phytochelatins
Skalová, Štěpánka ; Barek, Jiří (advisor) ; Labuda, Ján (referee) ; Trnková, Libuše (referee)
Present Ph.D. Thesis is focused on the development of electrochemical methods for determination of anticancer drugs using various types of membranes for their preliminary separation. Furthermore, this Thesis reports the study of transport mechanisms of heavy metals in the presence of phytochelatins across biological membranes. Sodium anthraquinone-2-sulphonate (AQS) was used as a model compound for its similar structure with anthraquinone-based (AQ-based) anticancer drugs (doxo/daunorubicin) and also due to its better availability. All these compounds can be easily electrochemically oxidized and/or reduced. Redox behaviour of AQS was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in a cathodic region on mercury meniscus modified (m-AgSAE) and polished silver solid amalgam (p-AgSAE) electrodes, Obtained results were used for the development of a micro-volume voltammetric cell (MVVC). Its applicability for voltammetric determination of anticancer drugs was verified by using doxorubicin (DX) as a model substance. The second part of this Thesis deals with therapeutic monitoring of anticancer drugs in the blood circulation of the patients. For pilot experiments, a liquid-flow system with dialysis catheter and amperometric detection was used. The flow rate of carrier...
Application of carbon based electrodes for electrochemical detection in flow system
Mika, Jan ; Dejmková, Hana (advisor) ; Fischer, Jan (referee)
Carbon is due to its electrochemical properties a favourite material for construction of electrodes suitable for detection in flow system. The two most often used techniques (coulometric and amperometric) will be discussed in this Thesis. Carbon paste electrodes (CPE) represent the amperometric detectors. CPE are unstable in the medium with high content of organic solvents, which might complicate their application in HPLC, where the mobile phase contains organic component. It is interesting, that glassy carbon paste electrodes are more stable under such conditions. The change of surface and response of the electrode caused by the effect of methanol are described in this Thesis along with the possible reason of stability of GCPE. Roughing of the surface exposed to methanol is demonstrated by confocal microscopy. This effect leads to increase of height of the peak, background current and noise and to the shift of peak potential to less positive values. These changes are dependent on the time of exposure and the concentration of methanol. Coulometric detectors work with high conversion effectiveness and sensitivity, but in case of their passivation, reactivation is a relatively complicated problem, often leading to the replacement of electrode material. Answer to this problem can be given by using...
Development of Novel Electrochemical Methods Using Various Membrane Materials for Monitoring of Selected Anticancer Drugs and Phytochelatins
Skalová, Štěpánka
Present Ph.D. Thesis is focused on the development of electrochemical methods for determination of anticancer drugs using various types of membranes for their preliminary separation. Furthermore, this Thesis reports the study of transport mechanisms of heavy metals in the presence of phytochelatins across biological membranes. Sodium anthraquinone-2-sulphonate (AQS) was used as a model compound for its similar structure with anthraquinone-based (AQ-based) anticancer drugs (doxo/daunorubicin) and also due to its better availability. All these compounds can be easily electrochemically oxidized and/or reduced. Redox behaviour of AQS was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in a cathodic region on mercury meniscus modified (m-AgSAE) and polished silver solid amalgam (p-AgSAE) electrodes, Obtained results were used for the development of a micro-volume voltammetric cell (MVVC). Its applicability for voltammetric determination of anticancer drugs was verified by using doxorubicin (DX) as a model substance. The second part of this Thesis deals with therapeutic monitoring of anticancer drugs in the blood circulation of the patients. For pilot experiments, a liquid-flow system with dialysis catheter and amperometric detection was used. The flow rate of carrier...
Development of Novel Electrochemical Methods Using Various Membrane Materials for Monitoring of Selected Anticancer Drugs and Phytochelatins
Skalová, Štěpánka
Present Ph.D. Thesis is focused on the development of electrochemical methods for determination of anticancer drugs using various types of membranes for their preliminary separation. Furthermore, this Thesis reports the study of transport mechanisms of heavy metals in the presence of phytochelatins across biological membranes. Sodium anthraquinone-2-sulphonate (AQS) was used as a model compound for its similar structure with anthraquinone-based (AQ-based) anticancer drugs (doxo/daunorubicin) and also due to its better availability. All these compounds can be easily electrochemically oxidized and/or reduced. Redox behaviour of AQS was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in a cathodic region on mercury meniscus modified (m-AgSAE) and polished silver solid amalgam (p-AgSAE) electrodes, Obtained results were used for the development of a micro-volume voltammetric cell (MVVC). Its applicability for voltammetric determination of anticancer drugs was verified by using doxorubicin (DX) as a model substance. The second part of this Thesis deals with therapeutic monitoring of anticancer drugs in the blood circulation of the patients. For pilot experiments, a liquid-flow system with dialysis catheter and amperometric detection was used. The flow rate of carrier...
Boron doped diamond and its utilization in electroanalysis of derivatives of aromatic compounds
Zavázalová, Jaroslava ; Schwarzová, Karolina (advisor) ; Šelešovská, Renáta (referee) ; Navrátil, Tomáš (referee)
This work is devoted to the study of boron doped diamond as electrode material, its properties and use in electroanalytical methods - in voltammetric and subsequently amperometric methods in combination with high performance liquid chromatography. The series of boron doped diamond films was tested with respect to the effect of boron concentration on their morphology, quality, electrochemical and spectral properties using scanning electron microscopy, atomic force microscopy, Raman spectroscopy, and cyclic voltammetry and differential pulse voltammetry. Further, the effect of boron concentration on the determination of selected substances was investigated, both for their oxidation (2-aminobiphenyl, benzophenone-3) and for their reduction (5-nitroquinoline). Furthermore, a voltammetric and amperometric method was developed for the determination of a mixture of aminobiphenyls and aminonaphthalenes using a boron doped diamond electrode. The effects of activation cleaning programs on the signal of benzophenone-3 were investigated using a boron doped diamond electrode, and the determination of benzophenone-3 on boron doped diamond electrode in the presence of the selected surfactant was studied. Boron doped diamond as carbon-based material was compared with other selected carbon materials such as glassy...
Development of Novel Electrochemical Methods Using Various Membrane Materials for Monitoring of Selected Anticancer Drugs and Phytochelatins
Skalová, Štěpánka ; Barek, Jiří (advisor) ; Labuda, Ján (referee) ; Trnková, Libuše (referee)
Present Ph.D. Thesis is focused on the development of electrochemical methods for determination of anticancer drugs using various types of membranes for their preliminary separation. Furthermore, this Thesis reports the study of transport mechanisms of heavy metals in the presence of phytochelatins across biological membranes. Sodium anthraquinone-2-sulphonate (AQS) was used as a model compound for its similar structure with anthraquinone-based (AQ-based) anticancer drugs (doxo/daunorubicin) and also due to its better availability. All these compounds can be easily electrochemically oxidized and/or reduced. Redox behaviour of AQS was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in a cathodic region on mercury meniscus modified (m-AgSAE) and polished silver solid amalgam (p-AgSAE) electrodes, Obtained results were used for the development of a micro-volume voltammetric cell (MVVC). Its applicability for voltammetric determination of anticancer drugs was verified by using doxorubicin (DX) as a model substance. The second part of this Thesis deals with therapeutic monitoring of anticancer drugs in the blood circulation of the patients. For pilot experiments, a liquid-flow system with dialysis catheter and amperometric detection was used. The flow rate of carrier...
Modification of carbon felt detector with copper microparticles
Baroch, Martin ; Dejmková, Hana (advisor) ; Schwarzová, Karolina (referee)
The first aim of this work was to develop copper modified carbon felt electrode for detection of amino acids, which are not electrochemically active on ordinary carbon electrodes. Phenylalanine solution at a concentration 1.0 mmol dm-3 was chosen as the testing solution. Electrode modified with electrochemical deposition of copper from mixture of copper(II) sulphate and sodium sulphate provided very low responses which were decreasing during first measurements, apparently because of insufficient amount of copper. Therefore, further experiments were performed using copper microparticles as a modifier. Copper microparticles activated in nitric acid at a concentration 80 mmol dm-3 were applied at carbon felt by several techniques and in different parts of the felt, i.e. by stirring the felt in microparticles suspension, by dripping of the suspension to the part of the felt in contact with capillary (proximal), between two parts of the carbon felt (sandwich) and at a part of the carbon felt in contact with electrolyte in a measuring cell (distal). Electrodes modified in the distal and in the sandwich arrangement were chosen as the best ones. In the last part, calibration dependences for phenylalanine in concentration range from 0.025 mmol dm-3 to 1.0 mmol dm-3 were measured on the last two electrodes....
Voltammetric and Amperometric Determination of Nitrophenols Using Boron-Doped Diamond Film Electrode
Karaová, Jana ; Barek, Jiří (advisor) ; Šelešovská, Renáta (referee) ; Jaklová Dytrtová, Jana (referee)
Presented Ph.D. Thesis is focused on the use of the boron-doped diamond (BDD) electrodes for voltammetric and amperometric determination of selected nitrophenols: 2-nitrophenol (2NP), 4-nitrophenol (4NP), and 2,4-dinitrophenol (2,4DNP). These compounds are listed as "priority pollutants" by United States Environmental Protection Agency (US EPA) due to their negative impact on living organisms and are mainly used in agriculture as plant growth stimulators. BDD electrodes are used for determination of wide range of electrochemically both reducible and oxidisable organic compounds and have become a popular electrode material thanks to its commercial availability and excellent mechanical and electrochemical properties. A differential pulse voltammetric method was developed for the determination of 2NP, 4NP and 2,4DNP at a BDD film electrode using electrochemical reduction and of 4NP and 2,4DNP using electrochemical oxidation. The method was successfully applied for the direct determination of these compounds in drinking and river water in the concentration range from 4×10-7 to 2×10-5 mol.L-1 . To improve the limit of quantification, a preconcentration by solid phase extraction from 100 mL (drinking and river water) and 1000 mL (drinking water) of water samples was used with limit of determination...
Development of electroanalytical methods for detection of cholesterol and 7-dehydrocholesterol
Benešová, Lenka ; Schwarzová, Karolina (advisor) ; Dejmková, Hana (referee)
The aim of this Thesis is development of electroanalytical methods for determination of cholesterol and 7-dehydrocholesterol on boron doped diamond electrodes based on electrochemical oxidation of products of acid-induced dehydration reaction. Two approches have been applied, relying on their detection in 0,1 mol.l-1 perchloric acid in acetonitril containing variable water content 0,43 % - 40 %. Cyclic voltammetry revealed substantial difference in oxidation peak pontecials for 7-dehydrocholesterol (+850 mV) and cholesterol (+1500 mV) in 0,1 mol.l-1 perchloric acid in acetonitrile containing 5 % of water. The limit of detection using differential pulse voltammetry were 6,19 µmol.l-1 a 19,2 µmol.l-1 for a mixture of 7-dehydrocholesterol and cholesterol, respectively. For flow injection analysis with amperometric detection (FIA-AD) the water content in run buffer, detection potencial and the distance between the capillary outlet and electrode surface in wall-jet arrangement of amerometric flow-through detection cell were optimized. Achieved detection limits are in range of 0,61 - 3,43 µmol.l-1 depending on the detection potencial and water concent in the run buffer. The developed FIA-AD method was used for determination of a model mixture solution of 7- dehydrocholesterol and cholesterol. Key words...

National Repository of Grey Literature : 13 records found   1 - 10next  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.